Silicones, Inc. GI-1000 with AHT a High Temperature Activator
This activator, when used in place of standard activator, can raise the maximum service temperature of GI-Series bases to as high as 450F. While some bases have a service temperature of 250F to 350F, GI-1000AHT can be used to increase the temperature resistance by approximately 100F.
Typical Properties
The properties described on the individual GI-Series data sheets will be consistent when using GI-1000 AHT, excluding the service temperature, which will be increased. GI-1000 AHT is sensitive to sulfur based clays and the cure will be inhibited unless originals made from such materials are carefully sealed